Watchguard 1 hour: burners failed to ignite or lost flame 5 times during a single heating demand.
1Likely causes
- Burners failing to ignite
- Flame lost repeatedly
2Safe DIY steps
- Confirm the gas supply to the furnace is on
- Techniciandiagnose ignition and flame sensing
3When to call a pro
Call a licensed HVAC technician: if the furnace enters Watchguard again.
Find a local HVAC pro →Other Lennox codes
Improper main ground, OR line voltage below 90 volts. Control will not respond to a heat call until voltage rises above 95 volts.
Circuit board failure or control wired incorrectly.
Main power polarity reversed. Switch line and neutral.
Pressure prove switch open, OR blocked inlet/exhaust vent, OR pressure switch closed before the combustion air inducer started.
Rollout switch open, OR 12-pin connector improperly attached.
Low flame signal: measures below 1.5 microamps. Replace flame sense rod.