Over-temperature (rollout) switch open: flames rolled out of the heat exchanger into the burner compartment.
§1Likely causes
- Insufficient venting through inlet or exhaust
- Loose or faulty wiring
- Unstable flame pattern
§2Safe DIY steps
- Techniciancheck pressure switches, inducer rpm, vent length and obstructions, gaskets
- Techniciancheck wiring, burner seals and heat exchanger for damage
§3When to call a pro
Call a licensed HVAC technician: always; the manual calls this a very serious problem to be repaired before operation continues.
Find a local HVAC pro →§4Other Rheem codes
One-hour lockout, caused by repeated failed ignition (11), water sensed (59), dead blower (61), internal fault (93), flame lost 5 times (13) or unexpected flame (14).
11RheemFailed ignition. After four failed attempts the control enters one-hour lockout (10).
12RheemLow flame sense: flame sense current is weak or marginal. Furnace keeps running.
13RheemFlame lost after established.
14RheemFlame present with gas valve off. Extremely critical; furnace will not operate.
30RheemOpen fuse, usually from a 24 VAC short to common or ground.