Rheem 45: Low pressure switch open with inducer on high speed

Ref. RHEEM-45 · From the Rheem furnace manual · Updated 2026-10-23

Status code45Rheem
What it means

Low pressure switch open with inducer on high speed.

Call a profurnace
How it shows: Dual 7-segment display: 45

Find a local HVAC pro →

§1Likely causes

  • Blocked or improperly terminated inlet/exhaust vents
  • Vent length or elbows exceed maximum
  • Faulty or disconnected inducer
  • Faulty control board (inducer relay)
  • Loose or faulty wiring
  • Disconnected, blocked, split or cut pressure switch hoses
  • Wind gusts
  • Faulty pressure switch

§2Safe DIY steps

  1. Check outdoor vent terminations for blockage
  2. Techniciancheck venting, inducer, hoses, wiring and pressure switch
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

§3When to call a pro

Call a licensed HVAC technician: if vents are clear and the code persists.

Find a local HVAC pro →