Rheem 60: Blower fault, blower can still run: blower at max speed/torque or temperature limit because static pressure is too high

Ref. RHEEM-60 · From the Rheem furnace manual · Updated 2026-10-23

Status code60Rheem
What it means

Blower fault, blower can still run: blower at max speed/torque or temperature limit because static pressure is too high.

Basic checks firstfurnace
How it shows: Dual 7-segment display: 60

Find a local HVAC pro →

§1Likely causes

  • Restricted or improperly designed ductwork
  • Dirty filter

§2Safe DIY steps

  1. Turn off power and clean or replace the filter
  2. Remove obstructions to airflow
  3. Technicianrepair ductwork so static pressure is within published values
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

§3When to call a pro

Call a licensed HVAC technician: if a clean filter does not clear the code.

Find a local HVAC pro →