Carrier 13: Limit circuit lockout: a limit or flame rollout switch was open longer than 3 minutes. Control auto-resets after 3 hours (see code 33)

From the Carrier furnace manual · Updated 2026-10-23

What it means

Limit circuit lockout: a limit or flame rollout switch was open longer than 3 minutes. Control auto-resets after 3 hours (see code 33).

⚠ Call a profurnace
How it shows: Status LED: 1 short flash(es) then 3 long flash(es) (code 13)

Find a local HVAC pro →

1Likely causes

  • Dirty filter or restricted duct system
  • Restricted vent or improper vent sizing
  • Loose blower wheel
  • Defective blower motor or capacitor
  • Defective switch or connections
  • Inadequate combustion air supply (flame rollout switch open)
  • Excessive wind

2Safe DIY steps

  1. Turn off power and check/replace a dirty air filter
  2. Make sure return and supply grilles are open and unobstructed
  3. Techniciancheck vent sizing and restrictions, blower wheel, blower motor/capacitor, switches and connections
  4. Technicianflame rollout switch requires manual reset only after the cause is found
⚠ Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

3When to call a pro

Call a licensed HVAC technician: if the furnace locks out again after replacing the filter, or if a rollout switch has tripped.

Find a local HVAC pro →