Carrier 31: Low (LPS) or high (HPS) pressure switch did not close or reopened

Ref. CARRIER-31 · From the Carrier furnace manual · Updated 2026-10-23

Status code31Carrier
What it means

Low (LPS) or high (HPS) pressure switch did not close or reopened.

Call a profurnace
How it shows: Status LED: 3 short flash(es) then 1 long flash(es) (code 31)

Find a local HVAC pro →

§1Likely causes

  • Excessive wind
  • Restricted vent or improper vent sizing
  • Defective inducer motor or low inducer voltage
  • Defective or miswired pressure switch
  • Inadequate combustion air supply
  • Disconnected or obstructed pressure tubing
  • Restricted or blocked condensate drainage, or water in sagging vent pipe
  • Low inlet gas pressure (if LGPS used)

§2Safe DIY steps

  1. Check that outdoor vent and intake terminations are clear
  2. Techniciancheck vent sizing, inducer, pressure switches and tubing
  3. Techniciancheck condensate drain and vent pipe slope
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

§3When to call a pro

Call a licensed HVAC technician: if vent terminations are clear and the code repeats.

Find a local HVAC pro →