Carrier 21: Gas heating lockout. Control will NOT auto-reset

Ref. CARRIER-21 · From the Carrier furnace manual · Updated 2026-10-23

Status code21Carrier
What it means

Gas heating lockout. Control will NOT auto-reset.

Call a profurnace
How it shows: Status LED: 2 short flash(es) then 1 long flash(es) (code 21)

Find a local HVAC pro →

§1Likely causes

  • Mis-wired gas valve
  • Stuck closed gas valve relay on control (defective control)
  • Short to gas valve wire

§2Safe DIY steps

  1. Turn off power and wait 5 minutes to retry
  2. Techniciancheck gas valve wiring and the control valve relay
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

§3When to call a pro

Call a licensed HVAC technician: always; this lockout does not clear on its own and points to a gas valve circuit fault.