Carrier 34: Ignition proving failure: flame not sensed during trial for ignition. Control tries 3 more times before lockout 14

Ref. CARRIER-34 · From the Carrier furnace manual · Updated 2026-10-23

Status code34Carrier
What it means

Ignition proving failure: flame not sensed during trial for ignition. Control tries 3 more times before lockout 14.

Call a profurnace
How it shows: Status LED: 3 short flash(es) then 4 long flash(es) (code 34)

Find a local HVAC pro →

§1Likely causes

  • Oxide buildup on flame sensor
  • Gas valve defective or turned off, or manual shut-off valve closed
  • Low inlet gas pressure
  • Inadequate flame carryover or rough ignition
  • Defective hot surface igniter
  • Control ground continuity problem (green/yellow wire must be connected to furnace sheet metal)
  • Flame sensor grounded

§2Safe DIY steps

  1. Check that the manual gas shut-off valve is open and the gas valve is ON
  2. Technicianclean flame sensor with fine steel wool and check flame current (0.5 microamp DC minimum, 4.0-6.0 nominal)
  3. Techniciancheck igniter, gas pressure and ground
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

§3When to call a pro

Call a licensed HVAC technician: if gas is on and the code persists.